Code: PRO1329
Heatsinks with clip system
Lega | BxS Dimensione | Peso al metro |
---|---|---|
1 | 1 | 119,36 |
2 | 2 | 99,84 |
3 | 3 | 95,84 |
4 | 4 | 93,58 |
5 | 5 | 92,72 |
6 | 6 | 92,19 |
7 | 7 | 91,82 |
8 | 8 | 91,56 |
9 | 9 | 91,37 |
10 | 10 | 91,26 |
Codice | KN MAX | I | F | H |
---|
Codice | KN MAX | I | F | H |
---|
Codice | KN MAX | I | F | H |
---|
Codice | KN MAX | I | F | H |
---|
Codice | KN MAX | I | F | H |
---|
Codice | KN MAX | I | F | H |
---|
Length: 76.00 mm
Weight: 2.28 kg/m
Weight A: 0.00 kg/m
Weight B: 0.00 kg/m
Height: 34.00 mm
Within this catalog, heat sinks are organized based on their shape and dimensions expressed in millimeters. Each profile is characterized by the following parameters:
- Weight: expressed in kilograms per meter of profile length (Kg/m).
- Length: indicated in millimeters and used for calculating thermal resistance (L).
- Width: also in millimeters, considered for calculating thermal resistance (°C/W), applicable only to high-efficiency heat sinks.
- Thermal Resistance in Natural Convection: expressed in °C/W with a temperature difference of 70°C (compared to an ambient temperature of 25°C).
- Thermal Resistance in Forced Convection: also expressed in °C/W, with an air velocity of 3 m/s and a temperature difference of 50°C.
The values of thermal resistance have been determined through a thermal simulation program designed to replicate realistic conditions. In particular:
- The heat source is uniformly distributed over approximately 50% of the dissipation surface, with central positioning on the heat sink.
- To maximize natural convection heat dissipation efficiency, the heat sink is designed with vertical fins. For horizontal installations, it is advisable to consider an increase of approximately 20% in thermal resistance.
- The surface of the heat sink is not subject to additional treatments.
Regarding black anodized heat sinks in natural convection, the thermal resistance is reduced by approximately 10%.
As the length of the heat sink increases, the thermal resistance decreases following a nonlinear law. The indicated values refer to the specified lengths; for different lengths, consult the “Length Correction Factor” graph to calculate the multiplication factor to be applied to the thermal resistance, both in natural and forced convection.